- Maximum number of boundaries is per upper and lower is 6, i.e. 12 boundaries max.
- Temperature boundary can be set to a maximum of 300°C
- Temperature boundary can be set to a minimum of -273.1°C
- There can not be a crossover between upper and lower temperature boundaries. Meaning that an upper boundary can not have a lower temperature value than a lower boundary and vice versa.
Step 3: Shipment Contacts Configuration
...
When a user needs to add more than 4 12 loggers to a shipment , then a batch of shipments will be created. This means that multiple identical shipments with up to 4 loggers per shipment are created. If a user adds e.g 6 loggers in the create shipment form and creates the shipment, two shipments will be created where the first shipment has 4 loggers and the second shipment has 2 loggers. When a batch of shipments is created, each shipment name gets the suffix "- {{no. of shipment}}/{{batch shipment count}}". When more than 4 loggers are added in the create shipment form, an info message appears informing the user of what will be done: "You are adding more than 4 loggers to the shipment. If you add more than 4 loggers to a shipment, multiple identical shipments will be created instead of one shipment with multiple loggers. Each shipment will have up to 4 loggers." After the batch of shipments have been created the user is then routed to the shipments list.
Once more than 12 loggers have been added to a shipment the user gets a warning that more than 12 loggers have been added to the shipment and upon shipment creation the shipment will be split up in to multiple shipments with maximum 12 loggers in each.
Once the shipment creation is completed multiple identical shipments are created differentiated by a suffix in the Shipment reference stating the number of the shipment and out of how many, e.g. "AWB 001-2587643 - 1/2" See below example of a batch shipment.
Total of 15 loggers were added to the shipment. The first shipment has 12 loggers and the second shipment in this case has 3 loggers.