View file | ||||
---|---|---|---|---|
|
...
Description
...
Specification
...
Available Sensors
...
- Temperature sensor
- Geographical location
- Battery status
...
Operating Environment
...
- -20°C to 50°C, 0-99% RH (noncondensing)
...
Temperature calibration range
...
- -20°C to 30°C
...
Temperature sampling rate
...
- 10 minute default log interval
...
Temperature measurement accuracy
...
- Resolution: 0.1°C
- Accuracy: ± 0.5°C
...
Controlant Cloud Reporting
...
- Samples are automatically uploaded to the Controlant Cloud at intervals ranging
from 1 hour to 12 hours
...
Log Memory Data Storage
...
- Stores 60 days of temperature log in memory when no cloud connection is available
...
General Characteristics
...
- ABS plastic enclosure
...
Physical Size
...
- 20mm x 61mm x 91mm (0.8in. x 2.4in x 3.6in)
- Weight: 100 g (0.22lbs)
...
Power Options
...
- Rechargeable lithium battery 1800mAH / UN38.3 certified
- Operates on a single charge from 10-60 days based on cloud reporting interval
...
Wireless
...
- GSM | 3G/2G
...
- CE
- FCC
- IC
- Anatel
- ACMA
- IFT
...
- Vodafone Global