Location | Exhibits | Gateway |
Warehouse Storage aisles | Exh. 4 Exh. 5 Exh. 6 | a) Place one gateway in every fifth (5) or sixth (6) storage aisles (one gateway to cover five to six storage aisles). b) Fasten the gateway upside down above the storage racks. Ideal location is on the load bearing beam in the ceiling. c) Use plastic cable ties to fasten the gateway d) If the warehouse stores water rich goods, the distance between gateways must be shorter
|
Walk in cooler | Exh. 7 Exh. 8 Exh. 9 | a) Gateway must be within 12m from the cooler b) Fasten the gateway at least above the traffic (forklifts etc.) c) Fasten the gateway with screw or cable ties Note. If if is difficult or inconvenient to place a gateway close to the cooler, a logger with a temperature probe can be used (CO 07.01 for EU). Then the logger is fasten outside of the cooler and the probe end is extended inside of the cooler |
Drive through freezer/cooler | Exh. 10 | a) Short/small storage room – Place the gateway outside of the freezer/cooler room wall b) Long/large storage room – Place the gateway outside of the freezer/cooler wall and extend the RF antennas inside the storage room Note: Never place a gateway in environment where the temperature is below 0°C |
Warehouse docking | a) Fasten the gateway at high point on a column, facing the docking area. b) If there is no obstacle for the RF signal, one gateway can cover up to 50m in both directions |
...