is simple to install a Controlant temperature monitoring system if guidelines is followed. Two types of devices must be installed, a) gateway and b) a logger. The gateway communicates with the loggers through RF (Radio Frequency) communication and uploads the measurement data to the Controlant Data Cloud through mobile cellular network every 10 minutes. The logger measures the temperature, stores the measurement data and uploads the data to the gateway.
It is important that the gateway has a good connection to the cellular network and the logger has a good RF connection to the gateway
Many things in the environment effects the cellular and the RF signal, such as:
Metal
Steel mesh (such as in concrete walls)
Metal shelfs
Metal walls
Water
Water rich products (such as fruits)
Human body
Moisture
Distance
Based on experience and signal measurements inside warehouses, following signal attenuation can apply:
Signal Obstacle
Signal Attenuation
Laminated metal wall
40%
Storage shelf with mixed goods
10% (can be higher, depending on the goods*)
Refrigerator or other types of coolers made of metal
20% to 40%
Reinforced concrete wall – 20cm
5%-20% (depending on the steel mesh size)
Free air between storage shelf's (10m distance)
20%
Free air between storage shelf's (20m distance)
30%
Free air between storage shelf's (50m distance)
40%
Storage cage (Wire gauge)
0% to 100%, depending on the mesh size**
Moving traffic (people, machinery etc)
3% to 20% (In some cases machinery can block the RF signal)
*Water rich products such as watermelons and lemons are challenging for RF signal
** If the mesh size in the wire gauge is the same as the RF wavelength (1/1, ½, ¾, ¼,…) then the wire gauge can block the RF signal. (RF wavelength for CE version CO 01.01 is 34,538 cm, For US version CO 11.01 the wavelength is from 32,305 to 33,126cm)
In a pharmacy, the following things can effect the RF signal